SUPERSERVER 6015B-3SUPERSERVER 6015B-T USER’S MANUAL1.0b SUPER®
NotesxSUPERSERVER 6015B-3/6015B-T User's Manual
A-6SUPERSERVER 6015B-3/6015B-T User's ManualNotes
Appendix B: BIOS POST CodesB-1This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories:
B-2SUPERSERVER 6015B-3/6015B-T User's ManualPOST Code Description18h 8254 timer initialization1Ah 8237 DMA controller initialization1Ch
Appendix B: BIOS POST CodesB-3POST Code Description5Ch Test RAM between 512 and 640 kB60h Test extended memory62h Test extended memory ad
B-4SUPERSERVER 6015B-3/6015B-T User's ManualPOST Code Description99h Check for SMART Drive (optional)9Ch Set up Power Management9Dh I
Appendix B: BIOS POST CodesB-5POST Code DescriptionD2h Unknown interruptD4h Check Intel Branding stringD8h Alert Standard Format initializ
B-6SUPERSERVER 6015B-3/6015B-T User's ManualNotes
Appendix C: ESB2 HostRAID SetupC-1 Appendix C ESB2 HostRAID SetupAfter all the hardware has been installed, you must fi rst confi gure Intel
C-2SUPERSERVER 6015B-3/6015B-T User's ManualThe Intel HostRAID Confi gurationsThe following types of Intel's HostRAID confi gurations are supp
Appendix C: ESB2 HostRAID SetupC-3Using the Intel ESB2 SATA RAID Utility ProgramCreating, Deleting and Resetting RAID Volumesa. After the system exits
Chapter 1 Introduction1-1 OverviewThe SuperServer 6015B-3/6015B-T is a high-end server comprised of two main subsystems: the SC815TQ-560
C-4SUPERSERVER 6015B-3/6015B-T User's Manualb. Specify a name for the RAID 0 set and press the <Tab> key or the <Enter> key to go to
Appendix C: ESB2 HostRAID SetupC-5Creating a RAID 1 Volumea. Select "Create RAID Volume" from the main menu and press the <Enter> key.
C-6SUPERSERVER 6015B-3/6015B-T User's ManualCreating a RAID 10 (RAID 1+ RAID 0)a. Select "Create RAID Volume" from the main menu and pr
Appendix C: ESB2 HostRAID SetupC-7Creating a RAID 5 Set (Parity)a. Select "Create RAID Volume" from the main menu and press the <Enter>
C-8SUPERSERVER 6015B-3/6015B-T User's ManualDeleting RAID Volume Warning: Be sure to back up your data before deleting a RAID set. You wi
Appendix C: ESB2 HostRAID SetupC-9Resetting to Non-RAID and Resetting a RAID HDD a. From the main menu, select item3-Reset Disks to Non- RAID, and pr
C-10SUPERSERVER 6015B-3/6015B-T User's ManualC-2 Installing the Windows XP/2000/2003 for systems with RAID FunctionsNew Operating System-Windo
Appendix D: Adaptec HostRAID Setup D-1 Appendix D Adaptec HostRAID Setup (X7DBR-E only)After all the hardware has been installed, you must fi rst
D-2SUPERSERVER 6015B-3/6015B-T User's ManualConfi guring SATA RAID1. Press the <Del> key during system bootup to enter the BIOS Setup Utilit
Appendix D: Adaptec HostRAID Setup D-3Adaptec Embedded SATA with HostRAID Controller DriverThe Adaptec Embedded Serial ATA RAID Controller adds SATA/
1-2SUPERSERVER 6015B-3/6015B-T User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6015B-3/6015B-T lies the X7DBR-3/X7DBR-E, a d
D-4SUPERSERVER 6015B-3/6015B-T User's ManualManaging ArraysSelect this option to view array properties, and confi gure array settings. To select t
Appendix D: Adaptec HostRAID Setup D-5Confi guring Disk DrivesYou may need to confi gure a disk drive before you can use it.Caution: Confi guring a disk
D-6SUPERSERVER 6015B-3/6015B-T User's Manual2. From the "Select Drives for Confi guring" List (shown below,) select the drives you want
Appendix D: Adaptec HostRAID Setup D-75. Read the warning message as shown in the screen below.6. Make sure that you have selected the correct disk
D-8SUPERSERVER 6015B-3/6015B-T User's ManualCreating ArraysBefore you create arrays, make sure that the disks for the array are connected and ins
Appendix D: Adaptec HostRAID Setup D-9Assigning Array PropertiesOnce a new array is completed, you can assign properties to the array. Caution: Once
D-10SUPERSERVER 6015B-3/6015B-T User's ManualNotes:1. Before adding a new drive to an array, be sure to back up any data stored on the new drive;
Appendix D: Adaptec HostRAID Setup D-11Adding a Bootable ArrayTo make an array bootable:1. From the Main menu, select Manage Arrays. 2. From the List
D-12SUPERSERVER 6015B-3/6015B-T User's ManualAdding/Deleting HotsparesTo add a Hotspare:Note: In order to rebuild a RAID (RAID 0 or RAID 1), you
Appendix D: Adaptec HostRAID Setup D-13Viewing Array PropertiesTo view the properties of an existing array:1. From the main menu, select Manage Array
1-3Chapter 1: Introductionmust have RAID support to enable the hot-swap capability and RAID function of the Serial ATA drives.PCI Expansion SlotsThe X
D-14SUPERSERVER 6015B-3/6015B-T User's ManualRebuilding ArraysNote 1: Rebuilding applies to Fault Tolerant array (RAID 1) only.If an array Build
Appendix D: Adaptec HostRAID Setup D-15Deleting ArraysWarning: Back up the data on an array before you delete it to prevent data loss Deleted arrays
D-16SUPERSERVER 6015B-3/6015B-T User's ManualUsing the Disk UtilitiesThe Disk Utilities enable you to format or verify the media of your Serial A
Appendix D: Adaptec HostRAID Setup D-17To format a disk:Note: The operation of Formatting Disk allows you to perform a low-level formatting of a hard
D-18SUPERSERVER 6015B-3/6015B-T User's ManualTo verify disk media:3. When the screen shown above displays, select Verify Disk Media and press &l
Appendix D: Adaptec HostRAID Setup D-19To Exit the Adaptec RAID Confi guration Utility1. Once you have completed RAID array confi gurations, press ESC
D-20SUPERSERVER 6015B-3/6015B-T User's ManualD-2 Installing Intel's ESB2 Driver by Adaptec and the OS a. Insert Supermicro's bootable
Appendix E: Software InstallationE-1Driver/Tool Installation Display ScreenNote: Click the icons showing a hand writing on paper to view the readme fi
E-2SUPERSERVER 6015B-3/6015B-T User's ManualFigure E-1. Supero Doctor Screen: Health InformationE-2 Confi guring Supero Doctor IIIThe Supero Docto
Appendix E: Software InstallationE-3Figure E-2. Supero Doctor Screen: Remote ControlNote: SD III Software Revision 1.0 can be downloaded from our Web
1-4SUPERSERVER 6015B-3/6015B-T User's ManualSAS/SATA SubsystemThe SC815TQ-560 chassis was designed to support four SAS (6015B-3) or SATA (6015B-T
E-4SUPERSERVER 6015B-3/6015B-T User's ManualNotes
F-1Appendix F: System Specifi cationsAppendix FSystem Specifi cationsProcessors Single or dual Intel® Xeon™ 5100/5000 Sequence processors at a fro
F-2SUPERSERVER 6015B-3/6015B-T User's ManualMotherboard 6015B-3: X7DBR-3 (Extended ATX form factor) 6015B-T: X7DBR-E (Extended ATX form
F-3Appendix F: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR
F-4SUPERSERVER 6015B-3/6015B-T User's ManualNotes
1-5Chapter 1: IntroductionFigure 1-1. Intel 5000P Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for deta
1-6SUPERSERVER 6015B-3/6015B-T User's Manual1-4 Contacting Super MicroHeadquarters Address: Super Micro Computer, Inc. 9
Chapter 2: Server Installation2-1 Chapter 2 Server Installation 2-1 OverviewThis chapter provides a quick setup
2-2SUPERSERVER 6015B-3/6015B-T User's ManualChoosing a Setup Location - Leave enough clearance in front of the rack to enable you to open t
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.Information in this document i
2-4SUPERSERVER 6015B-3/6015B-T User's Manual2-4 Installing the System into a RackThis section provides information on installing the 6015B-3/601
Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a
2-6SUPERSERVER 6015B-3/6015B-T User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackTo install the SuperServe
2-8SUPERSERVER 6015B-3/6015B-T User's Manual2-5 Checking the Serverboard SetupAfter you install the 6015B-3/6015B-T in the rack, you will need t
Chapter 2: Server Installation2-9Figure 2-5. Accessing the Inside of the System
2-10SUPERSERVER 6015B-3/6015B-T User's Manual2-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the S
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS/SA
3-2SUPERSERVER 6015B-3/6015B-T User's Manual3-3 Control Panel LEDsThe control panel located on the front of th SC815TQ-560 chassis has fi ve LEDs.
Chapter 3: System Interface3-3 Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illu
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the inst
3-4SUPERSERVER 6015B-3/6015B-T User's ManualNotes
Chapter 4: System Safety4-1 Chapter 4 System Safety!Basic electrical safety precautions should be followed to protect yourself from
SUPERSERVER 6015B-3/6015B-T User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety: Keep the area around t
Chapter 4: System Safety4-34-3 ESD Precautions Electrostatic discharge (ESD) is generated by two objects with different electrical charges co
SUPERSERVER 6015B-3/6015B-T User's Manual4-44-4 Operating Precautions Care must be taken to assure that the chassis cover is in place wh
Chapter 5: Advanced Serverboard Setup5-1 Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install pro
5-2SUPERSERVER 6015B-3/6015B-T User's ManualIMPORTANT! Always connect the power cord last and remove it fi rst before add-ing, removing or changin
Chapter 5: Advanced Serverboard Setup5-3Socket keyCPU installed in socketPnP cap released from load plate3. Use your thumb and your index fi nger to ho
5-4SUPERSERVER 6015B-3/6015B-T User's ManualWarning! We do not recommend that the CPU or the heatsink be removed. However, if you do need to un
Chapter 5: Advanced Serverboard Setup5-55-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the ser
SUPERSERVER 6015B-3/6015B-T User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general ov
5-6SUPERSERVER 6015B-3/6015B-T User's ManualFigure 5-1. Front Control Panel Header Pins (JF1)Connecting the Control PanelJF1 contains header pins
Chapter 5: Advanced Serverboard Setup5-75-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below
5-8SUPERSERVER 6015B-3/6015B-T User's ManualFigure 5-3b. Top View of DDR Slot Figure 5-3a. Installing DIMM into SlotTo Install: Insert module ve
Chapter 5: Advanced Serverboard Setup5-95-6 Adding PCI Cards1. PCI Expansion SlotsThe X7DBR-3/X7DBR-E has two Universal PCI slots, each of which suppo
5-10SUPERSERVER 6015B-3/6015B-T User's ManualFigure 5-4. SUPER X7DBR-3/X7DBR-E Layout(not drawn to scale)5-7 Serverboard DetailsSUPER X7DBR-3
Chapter 5: Advanced Serverboard Setup5-11X7DBR-3/X7DBR-E Quick ReferenceJumper Description Default Setting J3P 3rd Power Fail Detect Open
5-12SUPERSERVER 6015B-3/6015B-T User's Manual5-8 Connector Defi nitions Power LED The Power LED connection is located on pins 15 and 16 of JF1. R
Chapter 5: Advanced Serverboard Setup5-13Overheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced war
5-14SUPERSERVER 6015B-3/6015B-T User's ManualReset Button The Reset Button connection is lo-cated on pins 3 and 4 of JF1. Attach it to the hardw
Chapter 5: Advanced Serverboard Setup5-15Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you o
vPrefaceNotes
5-16SUPERSERVER 6015B-3/6015B-T User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located bes
Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is desig-nated JWOL. See the table on the right for pin defi nitions. You
5-18SUPERSERVER 6015B-3/6015B-T User's ManualJLAN1/2 (Ethernet Ports)Two Ethernet ports (designated JLAN1 and JLAN2) are located beside the VGA p
Chapter 5: Advanced Serverboard Setup5-195-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used
5-20SUPERSERVER 6015B-3/6015B-T User's ManualJLAN Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the onboard Ether
Chapter 5: Advanced Serverboard Setup5-21Compact Flash Master/Slave The JCF1 jumper allows you to as-sign either master or slave status to a compact fl
5-22SUPERSERVER 6015B-3/6015B-T User's Manual5-11 Floppy, IDE, SATA and SAS Drive ConnectionsNote the following when connecting the fl oppy and h
Chapter 5: Advanced Serverboard Setup5-23IDE ConnectorsThere are no jumpers to con-fi gure the onboard IDE1 and IDE2 connectors. See the table on the
5-24SUPERSERVER 6015B-3/6015B-T User's ManualSAS Ports (X7DBR-3 only) There are eight Serial Attached SCSI ports on the motherboard (SAS0~3 and S
Chapter 6: Advanced Chassis Setup6-1Chapter 6Advanced Chassis Setup This chapter covers the steps required to install components and perform m
viTable of ContentsPrefaceAbout This Manual ... ii
6-2SUPERSERVER 6015B-3/6015B-T User's ManualFigure 6-1. Chassis: Front and Rear ViewsSystem Reset6-2 Control PanelThe control panel (located on
Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 40-mm heavy duty counter-rotating fans provide the cooling for the SuperServer 6015B-3/6015B-T
6-4SUPERSERVER 6015B-3/6015B-T User's ManualFigure 6-2. System Cooling Fans6-4 Drive Bay Installation/RemovalRemoving the Front BezelIf your sys
Chapter 6: Advanced Chassis Setup6-5Accessing the Drive BaysSAS/SATA Drives: Because of their hotswap capability, you do not need to access the inside
6-6SUPERSERVER 6015B-3/6015B-T User's ManualSAS/SATA Drive Installation1. Mounting a SAS/SATA drive in a drive carrier The SAS/SATA drives ar
Chapter 6: Advanced Chassis Setup6-72. Installing/removing hot-swap SAS/SATA drives The SAS/SATA drive carriers are all easily accessible at the
6-8SUPERSERVER 6015B-3/6015B-T User's ManualDVD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened to gain full access
Chapter 6: Advanced Chassis Setup6-96-5 Power SupplyThe SuperServer 6015B-3/6015B-T has a single 560 watt power supply, which is auto-switching capabl
6-10SUPERSERVER 6015B-3/6015B-T User's ManualFigure 6-6. Removing/Replacing the Power SupplyScrews on inside edge
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the Phoenix BIOS™ Setup utility for the X7DBR-3/X7DBR-E. The Phoenix R
Chapter 4: System Safety 4-1 Electrical Safety Precautions ... 4-14-2 Gene
7-2SUPERSERVER 6015B-3/6015B-T User's Manual7-2 Running SetupDefault settings are in bold text unless otherwise noted.The BIOS setup options desc
Chapter 7: BIOS7-3Main BIOS Setup MenuMain Setup FeaturesSystem TimeTo set the system date and time, key in the correct information in the appropriate
7-4SUPERSERVER 6015B-3/6015B-T User's ManualIDE Channel 0 Master/Slave, IDE Channel 1 Master/Slave, SATA Port2 and SATA Port3These settings allo
Chapter 7: BIOS7-5CHS FormatThe following items will be displayed by the BIOS:TYPE: This item displays the type of IDE or SATA Device.Cylinders: This
7-6SUPERSERVER 6015B-3/6015B-T User's ManualParallel ATAThis setting allows the user to enable or disable the function of Parallel ATA. The opt
Chapter 7: BIOS7-7System MemoryThis display informs you how much system memory is recognized as being present in the system.Extended MemoryThis displa
7-8SUPERSERVER 6015B-3/6015B-T User's ManualBoot FeaturesAccess the submenu to make changes to the following settings.QuickBoot ModeIf enabled,
Chapter 7: BIOS7-9Memory CacheCache System BIOS AreaThis setting allows you to designate a reserve area in the system memory to be used as a System B
7-10SUPERSERVER 6015B-3/6015B-T User's Manualor written into the L1, L2, L3 cache inside the CPU to speed up CPU operations. Select "Uncache
Chapter 7: BIOS7-11Slot#6 PCI-X 133MHz, Slot E1 x8, Slot E2 x4 and Slot E3 x8 Access the submenu for each of the settings above to make changes to th
viiiATX PS/2 Keyboard and PS/2 Mouse Ports ... 5-16Overheat LED ...
7-12SUPERSERVER 6015B-3/6015B-T User's ManualMemory Branch ModeThis option determines how the two memory branches operate. System address space c
Chapter 7: BIOS7-13Advanced Processor OptionsAccess the submenu to make changes to the following settings. CPU SpeedThis is a display that indicates
7-14SUPERSERVER 6015B-3/6015B-T User's ManualAdjacent Cache Line Prefetch (Available when supported by the CPU.)The CPU fetches the cache line fo
Chapter 7: BIOS7-15InterruptThis setting allows you to select the IRQ (interrupt request) for serial port A. The options are IRQ3 and IRQ4. Serial Po
7-16SUPERSERVER 6015B-3/6015B-T User's ManualDMI Event LoggingAccess the submenu to make changes to the following settings. Event Log ValidityTh
Chapter 7: BIOS7-17Console Redirection Access the submenu to make changes to the following settings. COM Port AddressThis item allows you to specify
7-18SUPERSERVER 6015B-3/6015B-T User's ManualHardware Monitor LogicNote: The Phoenix BIOS will automatically detect the type of CPU(s) and hardw
Chapter 7: BIOS7-19Hardware Monitor LogicCPU Temperature Threshold (See note on page 7-18.)This option allows the user to set a CPU temperature thres
7-20SUPERSERVER 6015B-3/6015B-T User's ManualHardware Monitor Logic (See note on page 7-18.)CPU Temperature ThresholdThis option allows the user
Chapter 7: BIOS7-21IPMI (This option available only when an IPMI card is installed in the system.)IPMI Specifi cation Version: This item displays the
Table of ContentsixChapter 7: BIOS 7-1 Introduction ...
7-22SUPERSERVER 6015B-3/6015B-T User's ManualOS Boot Watch DogSet to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled.Ti
Chapter 7: BIOS7-23Realtime Sensor DataThis feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of va
7-24SUPERSERVER 6015B-3/6015B-T User's Manual7-5 SecurityChoose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You
Chapter 7: BIOS7-25Password on BootThis setting allows you to require a password to be entered when the system boots up. The options are Enabled (pas
7-26SUPERSERVER 6015B-3/6015B-T User's Manual7-7 ExitChoose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should s
A-1Appendix A: BIOS POST Messages Appendix A BIOS POST MessagesDuring the Power-On Self-Test (POST), the BIOS will check for problems. If a p
A-2SUPERSERVER 6015B-3/6015B-T User's ManualSystem CMOS checksum bad - Default confi guration usedSystem CMOS has been corrupted or modifi ed incor
A-3Appendix A: BIOS POST MessagesSystem cache error - Cache disabledRAM cache failed and BIOS disabled the cache. On older boards, check the cache jum
A-4SUPERSERVER 6015B-3/6015B-T User's ManualFixed Disk nFixed disk n (0-3) identifi ed.Invalid System Confi guration DataProblem with NVRAM (CMOS)
A-5Appendix A: BIOS POST MessagesPress <F1> to resume, <F2> to Setup, <F3> for previous Displayed after any recoverable error messag
Kommentare zu diesen Handbüchern